Fire insulation and painting

brandisolering-malning

Scope of Work: fix and repair the fire insulation and painting works.

A cement-based, with construction cement STD P reinforced polymer powder materials have been used. The sludge provides very good adhesion between the punch and use the underlying concrete. Before the application was carried out must be solid base, grease and dust free. It is also before removing thick layers of laitance, loose, porous surfaces and cracked concrete. Important to also remove the carbonated concrete in connection with the reinforcement and concrete with high chloride content. Prior to application of slurry had the concrete förvattnas to eliminate the risk of dehydration and other complications. A mineral rapid repair mortar has been used in restorations, thickness 3-40 mm, the product has an integrated corrosion protection. Finally, an impregnation performed at a hydrofoberingsgel which has the following features: strong reduction of water uptake and absorption of water in the dissolved harmful substances. Protective Effect of frost and tösalter. Good alkali resistance. Very low volatility. Hydrofoberingsgelen meets all the requirements of TK Bro 2009 and SS EN 1504-2.

 

Requirements:
BSK 07
NTS 11 Protective Coatings.



 

Photos

Rostskyddsmålning av broRostskyddsmålning av gångbromalningsprojekt-gangbro_malning av brorostskyddsmalning-av-djurobron_malning-av-balkkonsoler-nasbypark_malning av brobalkarmalning av danvikstullsbrontakmalningcisternmalning_malning-av-cisterner-petrolea-2006malning-av-cisterner-utvändigtmalning-av-cisternerbottenshell-lidingo-cistern_coop-sodertalje-platfasad_malning-kemetyl-sodertaljetankmalning1_rostskyddsmalning-av-cistenerrostskyddsmalning-av-tankrostskyddsmalning-av-tank